• Call Us: +44 (0)1452 540130

DC Motor Fan Driven Heat Exchangers

Home » DC Motor Fan Driven Heat Exchangers
dc-fan-driven-heat-exchangers-featured

Mobile, MG Air, KBV, Drain,
HPA & HPV Series

All models in the DC Fan Driven Heat Exchangers category feature rugged bar & plate construction. This design provides high performance cooling in a compact size. Other standard features of these coolers include low fouling non-louvered air fins and long life DC motors.

Temperature Switch Options (others available on request)
emmegi-temperature-switches-TM4-A1

TM4 A1

DIN CONNECTOR
emmegi-temperature-switches-TMS6

TMS6

FAN REVERSING
Mobile Series DC Fan Driven Heat Exchangers
dc-sbv-series-heat-exchangers-emmegi
Full Range (.55 kW/°C) Product Line
Most Cost Effective Model Series
V Models Include 1.5 or 3 bar Internal Bypass
Highest Performance to Size Offered
12v & 24v Motor Options Available
MG Air, KBV & Drain Series DC Fan Driven Heat Exchangers
Traditional Design with Powder Painted Housing
Up to 0.9 kW/°C
Optional Foot Mounting Brackets
2000KBV Models Include 1.5 or 3 bar Internal Bypass
12v & 24v Motor Options Available
dc-2000kbv-series-heat-exchangers-emmegi
HPA & HPV Series DC Fan Driven Heat Exchangers
dc-hpv-series-heat-exchangers-emmegi
Welded Foot Mounting Brackets Standard
Cooler Stands Vertically Offering Substantially Reduced Footprint
Up to 1.7 kW/°C
HPV Models Include 1.5 or 3 bar Internal Bypass
12v &; 24v Motor Options Available
Technical Data

Integrated Bypass Valve

emmegi-heat-exchangers-bypass-valveNeed for external valves, related fittings, and hoses are eliminated with Emmegi’s fully integrated bypass check valve that protects against excessive back pressure during cold weather start up and intermittent flow surges.

Compatable Fluids

Mineral Oils: HL & HLP
Water-Oil Emulsion
Water – Glycol
Consult Factory for Other Fluids

Ratings

Operating Pressure: 20 bar
Test Pressure: 35 bar
Max. Operating Temperature: 120°C